100KW/215KWH Cabinet BESS Integrator

Product Features

  • The H098 is a 215kWh battery energy storage system with a 100kW integrated PCS — a compact, air-cooled BESS cabinet for commercial and industrial sites that want lower energy bills, backup power and solar self-consumption in one unit.Key Features:
    – 215kWh capacity with 100kW rated power, all-in-one cabinet design
    – Air-cooled thermal management, no complex liquid cooling infrastructure
    – Solar-ready: integrates with PV for higher self-consumption
    – Peak shaving and off-peak charging to cut demand charges
    – Cloud-based remote monitoring via phone and computer
    – Compact footprint 2414 × 1297 × 1910 mm with hoisting points for easy installation
    – Certified to Malaysian SIRIM (MyHIJAU Mark) for Southeast Asian markets
    – OEM/ODM and wholesale orders welcome

Product Description

215kWh / 100kW · Commercial & Industrial BESS

H098 215kWh
Commercial & Industrial
Battery Storage Cabinet

A single air-cooled outdoor cabinet integrating a 215kWh battery and a 100kW power
conversion system — just 1910 × 1297 × 2414 mm on the ground.
Ideal for factories, shopping malls, hotels, EV charging plazas and office parks that
need to cut electricity bills, secure backup power and make full use of rooftop solar,
without the complexity of a containerized project.

H098 215kWh commercial and industrial battery energy storage cabinet
MAIN VISUAL · 2400×1800 · Outdoor air-cooled cabinet, industrial setting at dusk, 30° front-side angle, whole cabinet in frame

Rated Energy

215kWh

Single-cabinet rated energy. The H098 series spans 50–315 kWh in five models.

Rated Power

100kW

Integrated PCS, 3P+N+PE output, 400V three-phase.

Ingress Protection

IP55

Fully sealed outdoor enclosure, ready for direct ground installation.

Discharge Temp.

−20~55°C

Discharging range. Charging range 0–50 °C.

IEC 63056
IEC 62477-1
IEC 62933-5-2
IEC 62933-2-1
EN 61000-6
RoHS 2.0
UN38.3
MSDS
SIRIM · MyHIJAU
H098 series in 50 / 100 / 150 / 215 / 315 kWh
OEM / ODM customization for export

Core Advantages

The six questions that decide the deal, answered up front

One cabinet removes on-site assembly. Air cooling removes liquid-cooling piping. Built-in MPPT removes external PV inverters. Every H098 advantage translates into less work on site and less money on the bill.

215kWh + 100kW in one cabinet

Battery, power conversion and energy management system sit in one enclosure, fully commissioned at the factory. On site you only run cables, connect to the grid and power up.

No separate PCS cabinet, no multi-vendor protocol integration

Air-cooled thermal management

Air cooling keeps the structure simple, reliable and maintenance-friendly. There is no liquid-cooling loop, no coolant top-up and no leak risk, so both the O&M threshold and the long-term cost are lower.

Well suited to C&I sites without a dedicated O&M team

Solar-ready, up to 120kW PV

A built-in MPPT accepts up to 850V with a 200–950V working range, so commercial rooftop solar connects directly — pushing self-consumption higher.

PV charging and off-peak charging run in parallel

Peak shaving, demand control

Charge on the off-peak tariff or from solar, discharge at peak. Monthly demand spikes are flattened, bringing down both demand charges and peak-rate energy costs.

Peak-valley arbitrage plus demand management

Cloud monitoring, anywhere

Track operating parameters, alarms and energy data from a phone or computer anywhere in the world. Local communication is RS485 / CAN.

No need to visit the site to read the meter

Compact footprint

1910 × 1297 × 2414 mm and 2850 kg — under 2.5 m² per cabinet, which is friendlier to space-constrained commercial sites.

IEC 63056 / IEC 62477-1 / IEC 62933 and Malaysian SIRIM certified

System Topology

Four connections, fully automatic operation

In a typical installation the H098 connects to solar, the grid, the cloud platform and your loads at the same time. The energy management system decides when to charge, when to discharge and when to hold reserve capacity — with no manual intervention.

H098 system topology
TOPOLOGY · 2000×1600 · Single-line diagram or a real installation photo: rooftop PV → storage cabinet → meter → loads / EV chargers

01

PV side · built-in MPPT

Rooftop solar connects straight into the MPPT inside the cabinet. Maximum input voltage 850V, working range 200–950V; the H098-215kWh accepts up to 120kW of PV.

02

Grid side · off-peak charging

Charges through the electricity meter at low tariff during off-peak hours. Charge rate and time windows are scheduled automatically by the EMS according to the local tariff policy.

03

Cloud platform · real-time monitoring

View every parameter from a phone or computer, with alarm push and historical data recall. Locally, the cabinet exchanges data with upstream systems over RS485 / CAN.

04

Load side · peak hours and outages

Discharges when electricity is expensive or the grid fails, supporting production equipment, air conditioning, lighting and EV chargers — avoiding downtime and lost charging sessions.

What’s Inside

What is inside the cabinet

The air-cooled outdoor enclosure packs the entire system into one unit, fully function-tested before it leaves the factory, ready to run on arrival.

Battery

LFP battery system

215kWh rated energy, 280Ah rated capacity, 768V DC platform, voltage range 672–864V DC.

BMS

Battery management system

Cell-level and module-level monitoring, balancing and protection, reporting live status to the EMS and the cloud platform.

PCS

100kW power conversion system

Bidirectional conversion, 100kW rated power, 138A rated output current, 3P+N+PE / AC400V / 50–60Hz output.

MPPT

PV input module

Up to 120kW PV input, 850V maximum, MPPT working range 200–950V, load voltage range 650–750V.

EMS

Energy management system

Automatically decides charging, discharging and reserve capacity, running to peak-valley tariffs and demand targets.

Enclosure

Air-cooled outdoor cabinet

IP55 protection, maximum altitude 2000m, 1910 × 1297 × 2414 mm, 2850 kg.

100KW/215KWH Cabinet BESS Integrator
DETAIL 01 · 1600×1200 · Cabinet front view with branding plate and IP55 rating label
100KW/215KWH Cabinet BESS Integrator
DETAIL 02 · 1600×1200 · Door open showing battery modules and the air duct / cooling unit
100KW/215KWH Cabinet BESS Integrator
DETAIL 03 · 1600×1200 · Distribution and control unit, communication ports (RS485 / CAN)

Specifications

H098 series specifications

One cabinet platform, five capacities. Size it to the load your site has today and scale up as consumption grows. The table below covers the complete H098 range.

ItemH098-50kWhH098-100kWhH098-150kWhH098-215kWhH098-315kWh
Battery System
Rated Voltage563.2V DC537.6V DC768V DC768V DC768V DC
Voltage Range440–642.4V DC420–537.6V DC600–876V DC672–864V DC672–864V DC
Rated Capacity90.9Ah200Ah206Ah280Ah412Ah
Rated Energy50.68kWh107.5kWh158kWh215kWh316.4kWh
Rated Charging Current45A100A206A140A206A
Rated Discharging Current45A100A206A140A206A
AC Side
Rated Power25kW50kW100kW100kW200kW
AC Output Voltage400V (-20%~+15%)400V (-20%~+15%)400V (-20%~+15%)320–460V320–460V
Rated Input Voltage3P+N+PE; AC400V3P+N+PE; AC400V3P+N+PE; AC400V3P+N+PE; AC400V3P+N+PE; AC400V
Rated Output Voltage3P+N+PE; AC400V3P+N+PE; AC400V3P+N+PE; AC400V3P+N+PE; AC400V3P+N+PE; AC400V
Rated Frequency50Hz / 60Hz50Hz / 60Hz50Hz / 60Hz50Hz / 60Hz50Hz / 60Hz
Rated Output Current36.2A72.5A138A138A276A
PV Input
Max. PV Input Voltage850V850V850V850V850V
Max. PV Power15kW+15kW38.4kW+38.4kW120kW120kW240kW
MPPT Working Voltage Range200–800V200–800V200–950V200–950V200–950V
MPPT Load Voltage Range450–750V450–750V650–750V650–750V650–750V
Mechanical & Environment
Dimensions (W×D×H)191×900×1964 mm1228×1125×2084 mm1600×1247×2414 mm1910×1297×2414 mm2153×1297×2414 mm
Weight900kg1700kg2300kg2850kg3500kg
Max. Altitude≤2000m≤2000m≤2000m≤2000m≤2000m
Protection RatingIP55IP55IP55IP55IP55
Charging Temperature0 °C ~ 50 °C0 °C ~ 50 °C0 °C ~ 50 °C0 °C ~ 50 °C0 °C ~ 50 °C
Discharging Temperature−20 °C ~ 55 °C−20 °C ~ 55 °C−20 °C ~ 55 °C−20 °C ~ 55 °C−20 °C ~ 55 °C
CommunicationRS485 / CANRS485 / CANRS485 / CANRS485 / CANRS485 / CAN
Certification
StandardsIEC 63056 / IEC 62477-1 / EN 61000-6 / IEC 62933-5-2:2020 / IEC 62933-2-1:2017 / RoHS 2.0 / UN38.3 / MSDS
Also certified to Malaysian SIRIM (MyHIJAU Mark)

Specifications are subject to the documents shipped with each unit. For a stamped datasheet for tender submissions, request it via the form at the bottom of this page.

Model Selection

Five capacities — how to choose

From 50kWh to 315kWh. Start with the load your site has today and expand as consumption grows — there is no need to pay up front for future capacity.

H098-50kWh

50.68kWh

25kW rated power

Small retail units, single-point backup, pilot projects

H098-100kWh

107.5kWh

50kW rated power

Mid-size workshops, hotels and office buildings for daily peak shaving

H098-150kWh

158kWh

100kW rated power

C&I sites with high demand charges and existing rooftop solar

H098-215kWhMost Popular

215kWh

100kW rated power

Factories, EV charging plazas and industrial parks — up to 120kW of direct PV

H098-315kWh

316.4kWh

200kW rated power

Heavy continuous production and sites with strict demand management targets

Saving Estimate

Run the numbers before you decide

Calculated for the H098-215kWh with one full cycle per day. Replace the peak-valley spread with your local figure and the result changes immediately.

Input · Assumptions (example — replace with local data)

System capacity215 kWh
Peak-valley tariff spread0.85 USD/kWh
Daily charge-discharge cycles1 per day
Operating days per year330 days
Rated power ceiling100 kW

Note: 0.85 USD/kWh is an example spread only — use your local time-of-use tariff. Demand charge reduction, higher PV self-consumption and backup power value are not included.

Estimated annual arbitrage revenue

$60.3K / yr

215 kWh × 0.85 USD/kWh × 330 days ≈ 60,307 USD

Estimated annual discharge

71.0MWh

215 kWh × 330 days ≈ 70,950 kWh

Payback depends on the landed equipment cost and your local tariff structure. We can run a tailored estimate on your actual tariff — just submit the form below.

Applications

Where it pays off fastest

Built for factory owners facing demand charges, operators in regions with unstable grids, solar installers who need storage for commercial rooftop projects, and EV charging operators who want to buffer peak-hour grid draw.

Factories & workshops

Peak shaving and demand charge reduction, avoiding expensive peak-rate draw.

Malls, hotels & offices

Backup power for critical loads, combined with tariff optimization.

EV charging plazas

Buffer grid draw during peak hours, easing instantaneous load and demand spikes.

Commercial rooftop solar

The built-in MPPT connects directly, pushing PV self-consumption higher.

Unstable grids, frequent outages

Keeps production equipment, air conditioning and lighting running through an outage.

Office parks

Centralized demand management that relieves transformer capacity pressure.

Projects

Project references

The three cards below are pre-built placeholders. Drop in photos and figures from delivered projects — on a B2B page this is the single most persuasive block for generating enquiries.

100KW/215KWH Cabinet BESS Integrator
[To fill] · 1600×1200 · Site photo (cabinet in its installed environment)

[To fill] Year[To fill] Country / City215kWh

[To fill] Project name or client type

[To fill] Two to three lines describing the outcome: the electricity problem before the upgrade and what changed after.

[To fill] e.g. “Demand charges down 32%, saving USD XX,XXX per year”

100KW/215KWH Cabinet BESS Integrator
[To fill] · 1600×1200 · Site photo (cabinet in its installed environment)

[To fill] Year[To fill] Country / City[To fill] Capacity

[To fill] Project name or client type

[To fill] Two to three lines describing the outcome: the electricity problem before the upgrade and what changed after.

[To fill] e.g. “PV self-consumption raised above 90%”

100KW/215KWH Cabinet BESS Integrator
[To fill] · 1600×1200 · Site photo (cabinet in its installed environment)

[To fill] Year[To fill] Country / City[To fill] Capacity

[To fill] Project name or client type

[To fill] Two to three lines describing the outcome: the electricity problem before the upgrade and what changed after.

[To fill] e.g. “X operating hours per year, zero downtime incidents”

Packing & Delivery

Every unit completes full-function testing before shipment

Reinforced export packaging with standard hoisting points protects the unit during sea and land transport, and our quality team runs multiple rounds of testing before delivery.

01

Requirements & selection

Capacity and connection method defined by site load, tariff structure and site conditions.

Scheduled per project

02

Production & configuration

Built to the confirmed configuration, with cell and module batch records kept on file.

Scheduled per project

03

Full-function testing

Every unit completes full-function testing before shipment, with multiple QA re-tests.

Completed pre-shipment

04

Reinforced export packing

Reinforced packing plus standard hoisting points, suited to sea and land transport.

Standard export packing

05

Shipping & arrival

Shipping documents and parameter sheets travel with the unit; we support customs clearance and site acceptance.

Per shipping schedule

06

Installation, grid tie & O&M

On-site wiring and grid connection, then onboarding to the cloud platform for remote monitoring.

Depends on site conditions

Downloads

Downloads

Get the documents you need for a tender or an internal evaluation. Enter your email address and we will send the relevant file.

PDF

H098 series datasheet

Full specifications for all five capacities, dimension drawings and wiring diagram.

DatasheetRequest →

PDF

IEC certification pack

IEC 63056 / IEC 62477-1 / IEC 62933 series certificates.

CertificatesRequest →

PDF

SIRIM · MyHIJAU

Certification documents for Malaysian market access.

MalaysiaRequest →

PDF

OEM / ODM partnership brief

Customization scope, minimum order quantity and delivery process.

PartnershipView →

FAQ

Frequently asked questions

The questions we are asked most often about sizing, connection, certification and shipping.

Is the H098 air-cooled or liquid-cooled?
Air-cooled. The system uses air-cooled thermal management, which means a simpler structure, high reliability and easier maintenance. Because there is no liquid-cooling loop, there is no coolant top-up and no leak risk — lower long-term O&M threshold and lower cost.
What load can a 215kWh cabinet carry?
The H098-215kWh has a built-in 100kW power conversion system and a 138A rated output current, delivering 3P+N+PE / AC400V / 50–60Hz. At full 100kW discharge it can run for just over two hours; actual duration depends on the real load profile.
Can it connect to rooftop solar directly? Do I need an extra inverter?
Yes, and no extra MPPT equipment is needed. A PV input module is already integrated in the cabinet, with a maximum input voltage of 850V and an MPPT working range of 200–950V. The H098-215kWh accepts up to 120kW of PV per cabinet.
Can the capacity be expanded later?
The H098 series covers five capacities: 50 / 100 / 150 / 215 / 315 kWh. We recommend starting with the load your site has today, then adding cabinets or moving to a larger model as consumption grows — there is no need to pay up front for future capacity.
Do I have to build a containerized project?
No. The H098 is an IP55 outdoor cabinet that can be installed directly on the ground — inside a plant yard, beside a car park or next to the distribution room — avoiding the civil works, lifting and secondary integration costs of a containerized project.
What certifications does it hold? Can I use it in a tender?
It is certified to IEC 63056 / IEC 62477-1 / EN 61000-6 / IEC 62933-5-2:2020 / IEC 62933-2-1:2017 / RoHS 2.0 / UN38.3 / MSDS, and holds the Malaysian SIRIM (MyHIJAU Mark). Stamped documents required for tenders can be requested via the form below.
How is it monitored? What if the local network is poor?
Through the cloud platform, you can view operating parameters and alarms from a phone or computer anywhere in the world. The cabinet’s local communication interfaces are RS485 / CAN, and it can also integrate with an existing on-site EMS or SCADA system.
How is it packed for shipping? Do you support OEM / ODM?
Every unit completes full-function testing before shipment, ships in reinforced export packaging with standard hoisting points, and is suited to both sea and land transport; our quality team runs multiple test rounds before delivery. OEM / ODM customization is supported — see the OEM / ODM partnership brief.

Get a Quote

Tell us about your site

Share your site type, location and approximate load, and we will come back with a capacity recommendation and a quotation.








We normally reply within one business day. Your details are used only for this enquiry.

About HUDA New Energy

HUDA New Energy (Huizhou Huada Technology Co., Ltd.) is a professional energy storage manufacturer with a complete product portfolio, covering portable power stations, household energy storage systems and commercial & industrial (C&I) energy storage solutions. Starting from lead-acid battery production, we have grown into an advanced lithium technology manufacturer, backed by multiple invention patents, utility model patents, design patents and High-Tech Enterprise certification.

With a professional R&D team, modern production facilities and a global energy monitoring data center, we provide reliable OEM/ODM services for customers worldwide. Factory visits are always welcome — contact us to schedule a tour or discuss your project.

HUDA New Energy headquarters and product showroom HUDA New Energy factory production lines for household and C&I energy storage HUDA New Energy invention patents and High-Tech Enterprise certificates

→ Learn more about our factory and certificates

Learn how we helped 100 top brands gain success.

Let's have a chat